Protector Diesel 30kva 50hz 3-Phase Standby Generator Features and Benefits
Automatic Backup for Large or Custom Homes
Looking to back up your entire home, or more items than usual? Consider the Protector Series gaseous automatic backup generator line. These units powers essential appliances and modern technologies during power outages, allowing homeowners and their families to continue living life comfortably and without interruption.
What Makes the Protector Series Such a Great Choice?
Generac's Protector Series offers benefits that competitors’ can’t match. Installation flexibility and cost reduction. Sophisticated, yet intuitive controls. Quiet operation. Supported by a 24/7/365 customer support team at our corporate headquarters, and a nationwide dealer network of more than 6,000 strong.
Keep your power and the peace with this 30kVA 50Hz generator
Packing a lot of power into a smaller footprint with less noise, ideal applications include larger homes, gas stations, convenience stores and other small businesses.
Key Features
- Generac's Evolution™ Controller: The most comprehensive available. The dual-line, tri-lingual LCD display allows for easy monitoring and management of generator functions.
- Standard aluminum, all-weather enclosure provides the ultimate protection from the elements. Aluminum’s corrosion resistance prolongs the life of your generator and is recommended for salt-air, coastal locations.
- Quiet-Test™ mode for a weekly self-test. Programmable feature validates proper operation. Runs at lower RPM for reduced noise, less fuel consumption and fewer emissions.
- Code Ready: The Protector Series offers compatibility with a variety of environments, with external vent and fill, a UL/CUL 142-listed, double-walled base tank, a UL/CUL 2200-listed generator, and a wide range of code-driven accessories.
- 5 Year Limited Warranty For automatic standby generators.
- External viewing window for easy inspection of generator status and breaker position.
- Removable doors for easy service and fuel fill access.
- Isochronous Governor: Electronic governor control for tight and precise load response and voltage (+/-1%) and frequency regulation.
Generator Specifications
- Type: Synchronous
- Rotor Insulation Class: F
- Stator Insulation Class: H
- Telephone Interference Factor (TIF): <50
- Alternator Output Leads 1-Phase: Three wire
- Alternator Output Leads 3-Phase: Six wire
- Bearings: Single Sealed Cartridge
- Coupling: Direct, Flexible Disc
- Excitation System: Direct
Voltage Regulation
- Type: Electronic
- Sensing: Single Phase
- Regulation: ±1%
- Features: Adjustable Voltage & Gair
Governor Specifications
- Type: Electronic Isochronous
- Steady State Regulation: ± 0.25%
Electrical System
- Battery Charge Alternator: 65 Amp
- Static Battery Charger: 2 Amp
- Recommended Battery (battery not included): Group 27F, 700 CCA; Group 31, 925 CCA batteries can also be used with 30KVA units
- System Voltage: 12 Volts
Generator Features
- Revolving field heavy duty generator
- Directly connected to the engine
- Operating temperature rise 120 °C (248 °F) above a 40 °C (104 °F) ambient
- Class H insulation is NEMA rated
- Class F insulation is NEMA rated
- All models fully prototype tested
Enclosure Features
- Aluminum weather protective enclosure: Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.
- Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries and maximize sound dampenina.
- Small, compact, attractive: Makes for an easy, eye appealing installation.
- SAE: Sound attenuated enclosure ensures quiet operation.
Engine Specifications
- Make: Perkins
- Model: In-line
- Cylinders: 4
- Displacement (Liters): 2.216 L
- Bore: 3.30 in. (84 mm)
- Stroke: 3.94 in. (100 mm)
- Compression Ratio: 23.3:1
- Intake Air System: Turbocharged / Aftercooled
- Cylinder Head Type: Cast Iron OHV
- Piston Type: Aluminum
Engine Lubrication Sysrem
- Oil Pump Type: Gear
- Oil Filter Type: Full flow spin-on cartridge
- Crankcase Capacity: 11.2 qt (10.6 l)
Engine Cooling System
- Water Pump: Pre-lubed, self-seating
- Fan Diameter: 18 in. (457.2 mm)
- Fan Mode: Pusher
- Fan Speed: 1650 RPM
Fuel System
- Fuel Type: Ultra Low Sulfur Diesel Fuel
- Fuel Pump Type: Mechanical Engine Driven Gear
- Injector Type: Mechanical|
- Fuel Supply Line: 0.31 in. (7.94 mm)
- Fuel Specification: ASTM
- Fuel Filtering: 25 microns
- Fuel Return Line: 0.19 in. (4.76 mm) (ID)
Tank Specifications
- Total Size: 68 gal. (257.4 L)
- Usable Size: 61 gal. (230.9 L)
- Run Time @ 1/2 Load: 44.5 hr
Weights And Dimensions
- Weight: 1726 lb. (783 kg)
- Dimensions (L x W xH): 77 × 35 x 57 in. (195 × 89 x 147 cm)
Generator Output Voltage/kW - 50 Hz
- 110/220 V, 1Ø, 1.0 pf: kVA (standby): 24; Amp (standby): 109; kVA (Prime): 19.2; Amp (Prime): 87; CB Size: 125
- 231/400 V, 3Ø, 0.8 pf: kVA (standby): 30; Amp (standby): 43; kVA (Prime): 19.2; Amp (Prime): 35; CB Size: 50
Surge Capacity in Amps
- 120/240 V, 10 Voltage Dip @ < 0.4 pf: 15% - 66; 30% - 168
- 120/208 V, 30 Voltage Dip @ < 0.4 pf: 15% - 59; 30% - 144
- 120/240 V, 30 Voltage Dip @ < 0.4 pf: 15% - 51; 30% - 125
- 277/480 V, 30 Voltage Dip @ < 0.4 pf: 15% - 26; 30% - 64
Engine Fuel Consumption
- 25% of rated load: 0.97 gal/hr; 3.67 l/hr
- 50% of rated load: 1.37 gal/hr; 5.19 l/hr
- 75% of rated load: 1.97 gal/hr; 7.46 l/hr
- 100% of rated load: 2.77 gal/hr; 10.49 l/hr
Engine Cooling
- Air flow (inlet air including alternator and combustion air in cfm/cmm): 2530 / 72
- System coolant capacity (liters/gal): 9.5/2.5
- Heat rejection to coolant (BTU per hr/MJ per hr): 128,638 / 135.7
- Maximum operation air temperature on radiator (°C / °F): 50 / 122
- Maximum ambient temperature (°C / °F): 50 / 122
Combustion Requirements
- Flow at rated power: 88 cfm (2.5 cmm)
Sound Emissions
- Sound output in dB(A) at 7 m (23 ft) with generator in exercise mode*: 65
- Sound output in dB(A) at 7 m (23 ft) with generator operating at normal load*: 70
Exhaust
- Exhaust flow at rated output: 296.6 cfm (8.4 cmm)
- Exhaust temperature at rated output: 930 °F (499 °C)
Engine Parameters
- Rated Synchronous: 1,500 rpm
- HP at rated kVA: 40.9
Power Adjustment for Ambient Conditions
- Temperature Deration: 3% for everv 5 °C above 25 °C or 1.7% for everv 5 °F above 77 °F
- Altitude Deration: 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
Controller Features
- 2-Line Plain Text Multilingual LCD Display: Simple user interface for ease of operation
- Mode Buttons: Auto: Automatic Start on Utility failure. Programmable 7 day exerciser
- Manual: Start with starter control, unit stays on. If utility fails, transfer to load takes place
- Off: Stops unit. Power is removed. Control and charger still operate
- Ready to Run/Maintenance Message: Standard
- Engine Run Hours Indication: Standard
- Programmable start delay between 2-1500 seconds: Standard (programmable by dealer only)
- Utility Voltage Loss/Return to Utility Adjustable: From 140-171 V / 190-216 V
- Future Set Capable Exerciser/Exercise Set Error Warning: Standard
- Run/Alarm/Maintenance Logs: 50 Events Each
- Engine Start Sequence: Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
- Starter Lock-out: Starter cannot re-engage until 5 seconds after engine has stopped
- Smart Battery Charger: Standard
- Charger Fault/Missing AC Warning: Standard
- Low Battery/Battery Problem Protection and Battery Condition Indicatior: Standard
- Automatic Voltage Regulation with Over and Under Voltage Protection: Standard
- Under-Frequency/Overload/Stepper Overcurrent Protection: Standard
- Safety Fused/Fuse Problem Protection: Standard
- Automatic Low Oil Pressure/High Oil Temperature Shutdown: Standard
- Overcrank/Overspeed (@ 72 Hz)/RPM Sense Loss Shutdown: Standard
- High Engine Temperature Shutdown: Standard
- Internal Fault/Incorrect Wiring Protection: Standard
- Common External Fault Capability: Standard
- Field Upgradeable Firmware: Standard