2024 Generac Guardian 3-Phase 20KW Automatic Standby Wifi #7077
Call for Price
Key Features
Availability
Brochure
Year2024
MakeGenerac
ModelGuardian 3-Phase 20KW Automatic Standby Wifi #7077
Product Features
Description
Guardian 3-Phase 20kw Generator features and Benefits
One of the most powerful air-cooled generators on the market today, the Guardian Series 3-Phase 20 kW Standby Generator can provide whole-house backup power for many homes.
Key Features
- Mobile Link™ Remote Monitoring FREE with every Guardian Series Home standby generator allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information, such as the current operating status and maintenance alerts.
- 5 Year Limited Warranty for automatic standby generators.
- True Power™ Technology delivers best-in-class power quality with less than 5 percent total harmonic distortion for clean, smooth operation of sensitive electronics and appliances.
- Generac generators and engines are engineered and built in the USA.
- Generac's G-Force Engine are purpose built, pressure-lubricated engine capable of handling the rigors of generator use, resulting in power that's more reliable and requires less routine maintenance than any other competitor.
- 24/7/365 Customer Support Team standing by all day, every day from our headquarters in Wisconsin to answer any questions you might have.
- Durable powder-coat finish helps make the sturdy, galvanneal steel enclosure perfect for all weather conditions
- Smart, User-Friendly Controls Generac’s Evolution™ Controller features a dual-line, multilingual LCD display allowing for easy monitoring of history, maintenance logs making it easier to manage your generator.
Engine
- Generac G-Force design: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
- Quiet-Test™: Greatly reduces sound output and fuel consumption during bi-weekly exercise.
- "Spiny-lok" cast iron cylinder walls: Rigid construction and added durability provide long engine life.
- Electronic ignition/spark advance: These features combine to assure smooth, quick starting every time.
- Full pressure lubrication system: Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval.
- Low oil pressure shutdown system: Shutdown protection prevents catastrophic engine damage due to low oil.
- High temperature shutdown: Prevents damage due to overheating.
Generator
- Revolving field: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
- Skewed stator: Produces a smooth output waveform for compatibility with electronic equipment.
- Displaced phase excitation: Maximizes motor starting capability.
- Automatic voltage regulation: Regulates the output voltage to ±1% prevents damaging voltage spikes.
- UL 2200 listed: For your safety.
Evolution™ Controls
- Two-line LCD multilingual display: Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
- Auto/Manual/Off illuminated buttons: Selects the operating mode and provides easy, at-a-glance status indication in any condition.
- Sealed, raised buttons: Smooth, weather-resistant user interface for programming and operations.
- Utility voltage sensing: Constantly monitors utility voltage, defaults 132 V dropout, 175 V pick up.
- Generator voltage sensing: Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
- Utility interrupt delay: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer.
- Engine warm-up: Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
- Engine cool-down: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
- Programmable exercise: Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
- Smart battery charger: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
- Electronic governor: Maintains constant 60 Hz frequency.
Unit
- SAE weather protective enclosure: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
- Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
- Small, compact, attractive: Makes for an easy, eye appealing installation, as close as 18"" away from a building.
Installation System
- 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
- Direct-to-dirt composite mounting pad: Complex lattice design prevents settling or sinking of the generator system.
- Integral sediment trap: Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Specifications - Generator
- Model: G007077-0
- Rated Maximum Continuous Power Capacity (LP): 20,000 Watts*
- Rated Maximum Continuous Power Capacity (NG): 17,000 Watts*
- Rated Voltage: 208
- Rated Maximum Continuous Load Current – 208 Volts (LP/NG): 69.4/59.0
- Main Line Circuit Breaker: 80 Amp
- Number of Rotor Poles: 2
- Total Harmonic Distortion: Less than 5%
- Phase: 3
- Rated AC Frequency: 60 Hz
- Power Factor: 0.8
- Battery Requirement (not included): 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum
- Unit Weight (lb/kg): 466/211
- Dimensions (L x W x H) in/mm: 48 x 25 x 29/1218 x 638 x 732
- Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load**: 67
- Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode**: 58
- Exercise duration: 5 min
Specifications - Engine
- Type of Engine: GENERAC G-Force 1000 Series
- Number of Cylinders: 2
- Displacement: 999 cc
- Cylinder Block: Aluminum w/ Cast Iron Sleeve
- Valve Arrangement: Overhead Valve
- Ignition System: Solid-state w/ Magneto
- Governor System: Electronic
- Compression Ratio: 9.5:1
- Starter: 12 Vdc
- Oil Capacity Including Filter: Approx. 1.9 qt/1.8 L
- Operating rpm: 3,600
- Fuel Consumption Natural Gas - ft³/hr (m³/hr) 1/2 Load: 219 (6.20)
- Fuel Consumption Natural Gas - ft³/hr (m³/hr) Full Load: 307 (8.69)
- Liquid Propane - ft3/hr (gal/hr) [l/hr] 1/2 Load: 87 (2.39) [9.03]
- Liquid Propane - ft3/hr (gal/hr) [l/hr] Full Load: 130 (3.56) [13.48]
Specifications - Controls
- Two-Line Plain Text Multilingual LCD Display: Simple user interface for ease of operation.
- Mode Buttons:Auto: Automatic Start on Utility failure. 7 day exerciser.
- Mode Buttons: Manual: Start with starter control, unit stays on. If utility fails, transfer to load takes place.
- Mode Buttons: Off: Stops unit. Power is removed. Control and charger still operate.
- Ready to Run/Maintenance Messages: Standard
- Engine Run Hours Indication: Standard
- Programmable start delay between 2-1500 seconds: Standard (programmable by dealer only)
- Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting): From 121-148 V/175-187 V
- Future Set Capable Exerciser/Exercise Set Error Warning: Standard
- Run/Alarm/Maintenance Logs: 50 Events Each
- Engine Start Sequence: Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
- Starter Lock-out: Starter cannot re-engage until 5 sec after engine has stopped.
- Smart Battery Charger: Standard
- Charger Fault/Missing AC Warning: Standard
- Low Battery/Battery Problem Protection and Battery Condition Indication: Standard
- Automatic Voltage Regulation with Over and Under Voltage Protection: Standard
- Under-Frequency/Overload/Stepper Overcurrent Protection: Standard
- Safety Fused/Fuse Problem Protection: Standard
- Automatic Low Oil Pressure/High Oil Temperature Shutdown: Standard
- Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown: Standard
- High Engine Temperature Shutdown: Standard
- Internal Fault/Incorrect Wiring Protection: Standard
- Common External Fault Capability: Standard
- Field Upgradable Firmware: Standard
Engine
Engine Type | GENERAC G-Force 1000 Series |
Displacement | 999 cc |
Dimensions
Length | 48 in. (1218 cm) |
Width | 25 in. (638 cm) |
Height | 29 in. (732 cm) |
Weight | 466 lb.(211 kg) |